Switch Configuration for storage and vSphere

Fabric OS (goals)
Fabos Version 5.3.1

Welcome to VMware Consultancy Services(vCloud Automation Center).

goals login: admin
Password:
goals:admin> switchshow
switchName:     goals
switchType:     26.2
switchState:    Online
switchMode:     Native
switchRole:     Principal
switchDomain:   1
switchId:       fffc01
switchWwn:      10:00:00:05:1e:35:7f:aa
zoning:         ON (configfile)
switchBeacon:   OFF

Area Port Media Speed State     Proto
=====================================
  0   0   id    N2   Online           F-Port  50:06:01:68:3e:e0:38:39
  1   1   --    N2   No_Module
  2   2   id    N2   Online           F-Port  10:00:00:00:c9:44:f1:af
  3   3   --    N2   No_Module
  4   4   --    N2   No_Module
  5   5   --    N2   No_Module
  6   6   --    N2   No_Module
  7   7   --    N2   No_Module
  8   8   id    N2   Online           F-Port  50:06:01:60:3e:e0:38:39
  9   9   --    N2   No_Module
 10  10   --    N2   No_Module
 11  11   --    N2   No_Module
 12  12   id    N2   No_Light
 13  13   --    N2   No_Module
 14  14   --    N2   No_Module
 15  15   --    N2   No_Module
goals:admin> zoneshow
Defined configuration:
 cfg:   configfile
                zone1; zone2
 zone:  zone1   Host_Node; Storage_SPA
 zone:  zone2   Host_Node; Storage_SPB
 alias: Host_Node
                10:00:00:00:c9:3e:ce:ac
 alias: Storage_SPA
                50:06:01:60:3e:e0:38:39
 alias: Storage_SPB
                50:06:01:68:3e:e0:38:39

Effective configuration:
 cfg:   configfile
 zone:  zone1   10:00:00:00:c9:3e:ce:ac
                50:06:01:60:3e:e0:38:39
 zone:  zone2   10:00:00:00:c9:3e:ce:ac
                50:06:01:68:3e:e0:38:39

goals:admin> zonedisable zone1
rbash: zonedisable: command not found
goals:admin>
goals:admin>
goals:admin>
goals:admin> cfgdisable configfile
error: Usage: cfgDisable
goals:admin> cfgDisable configfile
error: Usage: cfgDisable
goals:admin> cfgDisable "configfile"
error: Usage: cfgDisable
goals:admin> cfgdisable "configfile"
error: Usage: cfgDisable
goals:admin> cfgDisable "configfile"
error: Usage: cfgDisable
goals:admin> cfgdelete "configfile"
goals:admin> zhoneshow
rbash: zhoneshow: command not found
goals:admin> zoneshow
Defined configuration:
 zone:  zone1   Host_Node; Storage_SPA
 zone:  zone2   Host_Node; Storage_SPB
 alias: Host_Node
                10:00:00:00:c9:3e:ce:ac
 alias: Storage_SPA
                50:06:01:60:3e:e0:38:39
 alias: Storage_SPB
                50:06:01:68:3e:e0:38:39

Effective configuration:
 cfg:   configfile
 zone:  zone1   10:00:00:00:c9:3e:ce:ac
                50:06:01:60:3e:e0:38:39
 zone:  zone2   10:00:00:00:c9:3e:ce:ac
                50:06:01:68:3e:e0:38:39

goals:admin> cfgdisable "configfile"
error: Usage: cfgDisable
goals:admin> cfgdisable
You are about to disable zoning configuration. This
action will disable any previous zoning configuration enabled.
Do you want to disable zoning configuration? (yes, y, no, n): [no] y
Updating flash ...
goals:admin> zoneshow
Defined configuration:
 zone:  zone1   Host_Node; Storage_SPA
 zone:  zone2   Host_Node; Storage_SPB
 alias: Host_Node
                10:00:00:00:c9:3e:ce:ac
 alias: Storage_SPA
                50:06:01:60:3e:e0:38:39
 alias: Storage_SPB
                50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> zonedelete "zone1"
goals:admin> zonedelete "zone2"
goals:admin> zoneshow
Defined configuration:
 alias: Host_Node
                10:00:00:00:c9:3e:ce:ac
 alias: Storage_SPA
                50:06:01:60:3e:e0:38:39
 alias: Storage_SPB
                50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> alidelete "Host_Node"
goals:admin> alidelete "Storage_SPA"
goals:admin> alidelete "Storage_SPB"
goals:admin> zoneshow
Defined configuration:
 no configuration defined

Effective configuration:
 no configuration in effect

goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin>
goals:admin> switchshow
switchName:     goals
switchType:     26.2
switchState:    Online
switchMode:     Native
switchRole:     Principal
switchDomain:   1
switchId:       fffc01
switchWwn:      10:00:00:05:1e:35:7f:aa
zoning:         OFF
switchBeacon:   OFF

Area Port Media Speed State     Proto
=====================================
  0   0   id    N2   Online           F-Port  50:06:01:68:3e:e0:38:39
  1   1   --    N2   No_Module
  2   2   id    N2   Online           F-Port  10:00:00:00:c9:44:f1:af
  3   3   --    N2   No_Module
  4   4   --    N2   No_Module
  5   5   --    N2   No_Module
  6   6   --    N2   No_Module
  7   7   --    N2   No_Module
  8   8   id    N2   Online           F-Port  50:06:01:60:3e:e0:38:39
  9   9   --    N2   No_Module
 10  10   --    N2   No_Module
 11  11   --    N2   No_Module
 12  12   id    N2   No_Light
 13  13   --    N2   No_Module
 14  14   --    N2   No_Module
 15  15   --    N2   No_Module
goals:admin> alicreate "HBA","10:00:00:00:c9:44:f1:af"
goals:admin> alicreate "SPA","50:06:01:60:3e:e0:38:39"
goals:admin> alicreate "SPB","50:06:01:68:3e:e0:38:39"
goals:admin> alishow
Defined configuration:
 alias: HBA     10:00:00:00:c9:44:f1:af
 alias: SPA     50:06:01:60:3e:e0:38:39
 alias: SPB     50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> zonecreate "HBA-SPA","HBA;SPA"
invalid name: "HBA-SPA"
goals:admin> zonecreate "HBA_SPA","HBA;SPA"
goals:admin> zonecreate "HBA_SPB","HBA;SPB"
goals:admin> zonecreate "HBA_SPA_SPB","HBA;SPA;SPB"
goals:admin> zoneshow
Defined configuration:
 zone:  HBA_SPA HBA; SPA
 zone:  HBA_SPA_SPB
                HBA; SPA; SPB
 zone:  HBA_SPB HBA; SPB
 alias: HBA     10:00:00:00:c9:44:f1:af
 alias: SPA     50:06:01:60:3e:e0:38:39
 alias: SPB     50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> cfgcreate "cfg1" "HBA_SPA"
error: Usage: cfgcreate "cfg1", "HBA_SPA"
goals:admin> cfgcreate "cfg1","HBA_SPA"
goals:admin> zoneshow
Defined configuration:
 cfg:   cfg1    HBA_SPA
 zone:  HBA_SPA HBA; SPA
 zone:  HBA_SPA_SPB
                HBA; SPA; SPB
 zone:  HBA_SPB HBA; SPB
 alias: HBA     10:00:00:00:c9:44:f1:af
 alias: SPA     50:06:01:60:3e:e0:38:39
 alias: SPB     50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> cfgadd "cfg1","HBA_SPB"
goals:admin> zoneshow
Defined configuration:
 cfg:   cfg1    HBA_SPA; HBA_SPB
 zone:  HBA_SPA HBA; SPA
 zone:  HBA_SPA_SPB
                HBA; SPA; SPB
 zone:  HBA_SPB HBA; SPB
 alias: HBA     10:00:00:00:c9:44:f1:af
 alias: SPA     50:06:01:60:3e:e0:38:39
 alias: SPB     50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> cfgadd "cfg1","HBA_SPA_SPB'
>
>
goals:admin> cfgadd "cfg1","HBA_SPA_SPB"

goals:admin> zoneshow
Defined configuration:
 cfg:   cfg1    HBA_SPA; HBA_SPB; HBA_SPA_SPB
 zone:  HBA_SPA HBA; SPA
 zone:  HBA_SPA_SPB
                HBA; SPA; SPB
 zone:  HBA_SPB HBA; SPB
 alias: HBA     10:00:00:00:c9:44:f1:af
 alias: SPA     50:06:01:60:3e:e0:38:39
 alias: SPB     50:06:01:68:3e:e0:38:39

Effective configuration:
 no configuration in effect

goals:admin> cfgsave
You are about to save the Defined zoning configuration. This
action will only save the changes on Defined configuration.
Any changes made on the Effective configuration will not
take effect until it is re-enabled.
Do you want to save Defined zoning configuration only?  (yes, y, no, n): [no] y
Updating flash ...
goals:admin> cfgenable "cfg1"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'cfg1' configuration  (yes, y, no, n): [no] y
zone config "cfg1" is in effect
Updating flash ...
goals:admin> zonesgh
rbash: zonesgh: command not found
goals:admin> zoneshow
Defined configuration:
 cfg:   cfg1    HBA_SPA; HBA_SPB; HBA_SPA_SPB
 zone:  HBA_SPA HBA; SPA
 zone:  HBA_SPA_SPB
                HBA; SPA; SPB
 zone:  HBA_SPB HBA; SPB
 alias: HBA     10:00:00:00:c9:44:f1:af
 alias: SPA     50:06:01:60:3e:e0:38:39
 alias: SPB     50:06:01:68:3e:e0:38:39

Effective configuration:
 cfg:   cfg1
 zone:  HBA_SPA 10:00:00:00:c9:44:f1:af
                50:06:01:60:3e:e0:38:39
 zone:  HBA_SPA_SPB
                10:00:00:00:c9:44:f1:af
                50:06:01:60:3e:e0:38:39
                50:06:01:68:3e:e0:38:39
 zone:  HBA_SPB 10:00:00:00:c9:44:f1:af
                50:06:01:68:3e:e0:38:39

goals:admin> switchshow
switchName:     goals
switchType:     26.2
switchState:    Online
switchMode:     Native
switchRole:     Principal
switchDomain:   1
switchId:       fffc01
switchWwn:      10:00:00:05:1e:35:7f:aa
zoning:         ON (cfg1)
switchBeacon:   OFF

Area Port Media Speed State     Proto
=====================================
  0   0   id    N2   Online           F-Port  50:06:01:68:3e:e0:38:39
  1   1   --    N2   No_Module
  2   2   id    N2   Online           F-Port  10:00:00:00:c9:44:f1:af
  3   3   --    N2   No_Module
  4   4   --    N2   No_Module
  5   5   --    N2   No_Module
  6   6   --    N2   No_Module
  7   7   --    N2   No_Module
  8   8   id    N2   Online           F-Port  50:06:01:60:3e:e0:38:39
  9   9   --    N2   No_Module
 10  10   --    N2   No_Module
 11  11   --    N2   No_Module
 12  12   id    N2   No_Light
 13  13   --    N2   No_Module
 14  14   --    N2   No_Module
 15  15   --    N2   No_Module
goals:admin> cfgactvshow

Effective configuration:
 cfg:   cfg1
 zone:  HBA_SPA 10:00:00:00:c9:44:f1:af
                50:06:01:60:3e:e0:38:39
 zone:  HBA_SPA_SPB
                10:00:00:00:c9:44:f1:af
                50:06:01:60:3e:e0:38:39
                50:06:01:68:3e:e0:38:39
 zone:  HBA_SPB 10:00:00:00:c9:44:f1:af
                50:06:01:68:3e:e0:38:39

goals:admin> license show
rbash: license: command not found
goals:admin> licenseshow
b99bddcezdcAAceo:
    Web license
RydzyzS99cSze0zO:
    Fabric license
zb9eRzzQR0cAfSW:
    Zoning license
goals:admin> portshow

Usage:
  portshow [/]
  OR
  portshow [ipif|arp|iproute|fciptunnel|iscsi|mode]
           [/]ge [] []

Args:    all| - Show All/ FCIP tunnels on this GigE port.
Optional Args:   -perf   Additional performance information.
                         Valid for portshow fciptunnel only.
                 -params Connection parameter information.
                         Valid for portshow fciptunnel only.
                 -ipsec  IKE and IPSec policy information
                         on IPSec enabled tunnels.
                         Valid for portshow fciptunnel only.

goals:admin> portshow 0
portName:
portHealth: No Fabric Watch License

Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x24b03       PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP LED ACCEPT FLOGI
portType:  4.2
portState: 1    Online
portPhys:  6    In_Sync
portScn:   32   F_Port
port generation number:    0
portId:    010000
portIfId:    43020000
portWwn:   20:00:00:05:1e:35:7f:aa
portWwn of device(s) connected:
        50:06:01:68:3e:e0:38:39
Distance:  normal
portSpeed: N2Gbps

LE domain: 0
FC Fastwrite: OFF
Interrupts:        438        Link_failure: 3          Frjt:         0
Unknown:           12         Loss_of_sync: 0          Fbsy:         0
Lli:               62         Loss_of_sig:  0
Proc_rqrd:         365        Protocol_err: 0
Timed_out:         0          Invalid_word: 0
Rx_flushed:        0          Invalid_crc:  0
Tx_unavail:        0          Delim_err:    0
Free_buffer:       0          Address_err:  0
Overrun:           0          Lr_in:        4
Suspended:         0          Lr_out:       4
Parity_err:        0          Ols_in:       4
2_parity_err:      0          Ols_out:      9
CMI_bus_err:       0

Port part of other ADs: No
goals:admin> portdisable 2
goals:admin> switchshow
switchName:     goals
switchType:     26.2
switchState:    Online
switchMode:     Native
switchRole:     Principal
switchDomain:   1
switchId:       fffc01
switchWwn:      10:00:00:05:1e:35:7f:aa
zoning:         ON (cfg1)
switchBeacon:   OFF

Area Port Media Speed State     Proto
=====================================
  0   0   id    N2   Online           F-Port  50:06:01:68:3e:e0:38:39
  1   1   --    N2   No_Module
  2   2   id    N2   In_Sync          Disabled
  3   3   --    N2   No_Module
  4   4   --    N2   No_Module
  5   5   --    N2   No_Module
  6   6   --    N2   No_Module
  7   7   --    N2   No_Module
  8   8   id    N2   Online           F-Port  50:06:01:60:3e:e0:38:39
  9   9   --    N2   No_Module
 10  10   --    N2   No_Module
 11  11   --    N2   No_Module
 12  12   id    N2   No_Light
 13  13   --    N2   No_Module
 14  14   --    N2   No_Module
 15  15   --    N2   No_Module
goals:admin> portenable 2
goals:admin> switchshow
switchName:     goals
switchType:     26.2
switchState:    Online
switchMode:     Native
switchRole:     Principal
switchDomain:   1
switchId:       fffc01
switchWwn:      10:00:00:05:1e:35:7f:aa
zoning:         ON (cfg1)
switchBeacon:   OFF

Area Port Media Speed State     Proto
=====================================
  0   0   id    N2   Online           F-Port  50:06:01:68:3e:e0:38:39
  1   1   --    N2   No_Module
  2   2   id    N2   Online           F-Port  10:00:00:00:c9:44:f1:af
  3   3   --    N2   No_Module
  4   4   --    N2   No_Module
  5   5   --    N2   No_Module
  6   6   --    N2   No_Module
  7   7   --    N2   No_Module
  8   8   id    N2   Online           F-Port  50:06:01:60:3e:e0:38:39
  9   9   --    N2   No_Module
 10  10   --    N2   No_Module
 11  11   --    N2   No_Module
 12  12   id    N2   No_Light
 13  13   --    N2   No_Module
 14  14   --    N2   No_Module
 15  15   --    N2   No_Module
goals:admin> errshow
Fabric OS: v5.3.1

2015/04/26-16:07:38, [LOG-1003], 1,, INFO, goals, The log has been cleared.

Type to continue, Q to stop:
errclear
2015/04/26-16:13:40, [ZONE-1024], 2,, INFO, goals, cfgSave completes successfully.


Type to continue, Q to stop:
2015/04/26-16:14:04, [ZONE-1022], 3,, INFO, goals, The effective configuration has changed to goals.

Type to continue, Q to stop:
2015/04/26-16:15:00, [ZONE-1024], 4,, INFO, goals, cfgSave completes successfully.


Type to continue, Q to stop:
2015/04/26-16:15:11, [ZONE-1022], 5,, INFO, goals, The effective configuration has changed to goals.

Type to continue, Q to stop:
2015/04/26-16:16:07, [ZONE-1024], 6,, INFO, goals, cfgSave completes successfully.


Type to continue, Q to stop:
2015/04/26-16:16:23, [ZONE-1022], 7,, INFO, goals, The effective configuration has changed to goals.

Type to continue, Q to stop:
2015/04/26-16:17:13, [ZONE-1024], 8,, INFO, goals, cfgSave completes successfully.


Type to continue, Q to stop:
2015/04/26-16:17:29, [ZONE-1022], 9,, INFO, goals, The effective configuration has changed to goals.

Type to continue, Q to stop:
2015/04/26-16:32:27, [SEC-1203], 10,, INFO, goals, Login information: Login successful via TELNET/SSH/RSH. IP Addr: 192.168.1.15

Type to continue, Q to stop:

goals:admin> tempshow
Sensor  State           Centigrade     Fahrenheit
  ID
=================================================
  1     Ok          44            111
  2     Ok          40            104
  3     Ok          40            104
  4     Ok          44            111
goals:admin> fanshow
Fan 1 is Ok, speed is 5625 RPM
Fan 2 is Ok, speed is 5532 RPM
Fan 3 is Ok, speed is 5625 RPM
Fan 4 is Ok, speed is 5443 RPM
goals:admin> firmwareshow
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v5.3.1
         v5.3.1
goals:admin> sfpshow
Port  0: id (sw) Vendor: IBM              Serial No: 53P147600P5SC
Port  1: --
Port  2: id (sw) Vendor: IBM              Serial No: 53P1476006FUB
Port  3: --
Port  4: --
Port  5: --
Port  6: --
Port  7: --
Port  8: id (sw) Vendor: IBM              Serial No: 53P147600AZQ9
Port  9: --
Port 10: --
Port 11: --
Port 12: id (sw) Vendor: IBM              Serial No: 53P1476006KQZ
Port 13: --
Port 14: --
Port 15: --
goals:admin> version
Kernel:     2.6.14
Fabric OS:  v5.3.1
Made on:    Fri Feb 22 21:11:08 2008
Flash:      Sat Jun 20 22:25:23 2009
BootProm:   4.5.3
goals:admin> help
aaaconfig                  Configure RADIUS for AAA services
ad                         Specifies all administration domain (AD)-level
                           operations
ag                         Configure the Access Gateway feature
agshow                     Displays the Access Gateway information registered
                           with the fabric
agtcfgdefault              Reset SNMP agent to factory default
aliadd                     Add a member to a zone alias
alicreate                  Create a zone alias
alidelete                  Delete a zone alias
aliremove                  Remove a member from a zone alias
alishow                    Print zone alias information
aptpolicy                  Get and set Advanced Performance Tuning policy
auditcfg                   Modifies and displays audit log filter
                           configuration.
authutil                   Get and set authentication configuration
backplanetest              Backplane connection test for multi-blade systems.
backport                   Test for back-end ASIC pair to ASIC pair links.
bannerset                  Set security banner
bannershow                 Display security banner
bcastshow                  Display broadcast routing information
bladebeacon                Enables or disables blade beaconing or displays the
                           current mode.
bladedisable               Disables all user ports on a blade.
bladeenable                Enables all User Ports on a blade.
burninerrclear             Clear errors that are stored in the non-volatile
                           storage
burninerrshow              Display errors that are stored in the non-volatile
                           storage
burninstatus               Display the diagnostics burnin status.
camtest                    Verify QuickLoop's Content Addressable Memory
                           (CAM).SID translation
centralmemorytest          Test ASIC central memory operation.
cfgactvshow                Display Effective zone configuration information
cfgadd                     Add a member to a configuration
cfgclear                   Clear all zone configurations
cfgcreate                  Create a zone configuration
cfgdelete                  Delete a zone configuration
cfgdisable                 Disable a zone configuration
cfgenable                  Enable a zone configuration
cfgremove                  Remove a member from a configuration
cfgsave                    Save zone configurations in flash
cfgshow                    Print zone configuration information
cfgsize                    Print size details of zone database
cfgtransabort              Abort zone configuration transaction
cfgtransshow               Print zone configurations in transaction buffer
chassisconfig              Display or set the chassis configuration
chassisname                Display or set the chassis's Name
chassisshow                Display all Field Replaceable Units (FRU)
chipregshow                Displays the port registers for a given chip
                           number.
cmemretentiontest          Data retention test of the central memory SRAMs.
cmitest                    Verify CMI bus between ASICs.
configdefault              Reset config to factory default
configdownload             Load switch config from a server
configshow                 Print switch config parameters
configupload               Save switch config to a server
configure                  Set switch config parameters
datatypeshow               Display available diagnostic data types.
date                       Print/set the system date and time
dbgshow                    Display debug levels of various modules
defzone                    Activates or deactivates a default zone
                           configuration.
diagclearerror             Clears diagnostics failure status.
diagcommandshow            Display diagnostic command descriptions.
diagdisablepost            Disable diagnostic POST.
diagenablepost             Enable diagnostic POST.
diagenv                    Diagnostic debug parameters management package.
diaghelp                   Display diagnostic command descriptions.
diagloopid                 Select the diagnostics loop ID.
diagmodeshow               Displays diagnostic mode configuration.
diagpost                   Displays the contents of port registers and
                           memories.
diagretry                  Sets diagnostic retry mode
diagsetburnin              Initializes the blade for a burnin run.
diagsetcycle               Set diagnostic script parameters.
diagsetesdmode             Set or display ESD mode.
diagsetshowtime            Set or display diagnostic show-time mode.
diagshow                   Display diagnostic status.
diagshowtime               Set or display diagnostic show-time mode.
diagstatus                 Display currently running diagnostic tests.
diagstopburnin             Terminate burnin run on a blade.
distribute                 Distributes data to switches in a fabric.
dlsreset                   Turn off the dynamic load sharing (DLS) option
dlsset                     Turn on the dynamic load sharing (DLS) option
dlsshow                    Display the state of the dynamic load sharing
                           option
dnsconfig                  Configure DNS service
enclosureshow              Display the switch enclosure attributes
errclear                   Clear error log
errdelimiterset            Sets the error log start and end delimiter for
                           messages sent to the console and syslog
errdump                    Print error log (no page breaks)
errfilterset               Sets a filter for an error log destination
errmoduleshow              Displays all the defined modules in the system
errshow                    Print error log
fabportshow                Display contents of a particular port's data
fabretryshow               Display retry count of various fabric commands
fabriclog                  Displays or manipulates the fabric log
fabricprincipal            Displays/Enables/Disables Principal Switch
                           Selection mode
fabricshow                 Print fabric membership info
fabstateclear              Clears the fabric state information
fabstateresize             Changes the number of state entries
fabstateshow               Displays the fabric state information
fabstatsshow               Displays the fabric statistics information
fabswitchshow              Display fabric switch state information
fandisable                 Disables a fan unit.
fanenable                  Enables a fan unit.
fanshow                    Print fan status
fastboot                   Reboot this switch and bypass POST
fastwritecfg               Configure FC fastwrite feature
fazoneadd                  Add a member to a fabric assist zone
fazonecreate               Create a fabric assist zone
fazonedelete               Delete a fabric assist zone
fazoneremove               Remove a member from a fabric assist zone
fazoneshow                 Print Fabric Assist Zone information
fcipchiptest               Functional Test of Components in FCIP Complex.
fciphelp                   Print FCIP help info
fcippathtest               Data Path Test of the FCIP complex.
fcping                     Sends a FC ELS ECHO request to a port
fcplogclear                Clear the FCP log
fcplogdisable              Disable logging of FCP events
fcplogenable               Enable logging of FCP events
fcplogshow                 Display FCP probing log information
fcpprobeshow               Display FCP probing information
fcprlsshow                 Display FCP RLS (read link state) information
fcrchiptest                Functional Test of FCR FPGA.
fcrconfigure               Sets FC Router configuration parameters.
fcrfabricshow              Displays FC Routers on a backbone fabric.
fcrlsancount               Display maximum LSAN zone limit.
fcrlsanmatrix              Manage LSAN fabric matrix configuration.
fcrpathtest                Data Path Test on Connection between FCR FPGA and
                           Central ASIC.
fcrphydevshow              Displays FC Router physical device information.
fcrproxyconfig             Displays or configures proxy devices presented by
                           an FC Router.
fcrproxydevshow            Displays FC Router proxy device information.
fcrresourceshow            Displays FC Router physical resource usage.
fcrrouterportcost          Displays FC Router route information.
fcrrouteshow               Displays FC Router route information.
fcrxlateconfig             Displays or persistently configures a translate
                           (xlate) domain's domain ID for both
                           EX_Port-attached fabric and backbone fabric.
fddcfg                     fddcfg manages the fabric data distribution
                           configuration parameters.
fdmicacheshow              Display abbreviated remote FDMI device information
                           according to remote domain ID
fdmishow                   Display detailed FDMI device information
ficonclear                 Clears contents of the specified FICON management
                           database
ficoncupset                Sets FICON-CUP parameters for a switch
ficoncupshow               Displays FICON-CUP parameters for a switch
ficonhelp                  Displays FICON commands
ficonshow                  Displays contents of the specified FICON management
                           database
filtertest                 Run frame filter test for bloom ASICs.
firmwarecommit             Commit firmware to stable storage
firmwaredownload           Download firmware into switch
firmwaredownloadstatus     Display the progress and status of firmwareDownload
firmwarerestore            Restore the old firmware in the switch
firmwareshow               Display firmware versions in the switch
fosconfig                  Enable/disable FabOS services
fporttest                  Functional test of F->N N->F point to point path.
framerpathtest             Tests data path between ASICs
frureplace                 Replace a Field Replacable Unit
fspfshow                   Print FSPF global information
fwalarmsfilterset          Configure alarms filtering for Fabric Watch
fwalarmsfiltershow         Show alarms filtering for Fabric Watch
fwclassinit                Initialize all Fabric Watch classes
fwconfigreload             Reload Fabric Watch configuration
fwconfigure                Configure Fabric Watch
fwfrucfg                   Configure FRU state and notification
fwhelp                     Print Fabric Watch help info
fwmailcfg                  Configure Fabric Watch Email Alert
fwportdetailshow           Create a report with detailed port information
fwsamshow                  Show availability monitor information
fwset                      Set port persistence time
fwsettocustom              Set boundary & alarm level to custom
fwsettodefault             Set boundary & alarm level to default
fwshow                     Show thresholds monitored and port persistence time
grep                       Linux grep command
h                          Print shell history
hadisable                  Disables the High Availability feature in the
                           switch.
hadump                     Displays information about the status of the High
                           Availability feature in the switch.
haenable                   Enables the High Availability feature in the switch
hafailover                 Forces the failover mechanism so that the Standby
                           Control Processor (CP)becomes the Active CP.
hashow                     Displays control processor (CP) status
hasyncstart                Enables HA state synchronization.
hasyncstop                 Disables the HA state synchronization.
help                       Print this list
historylastshow            Displays last history record
historymode                Display or set the mode of the history log
historyshow                Displays entire history log
httpcfgshow                Used to show the version of the Java plug-in used
                           by the Webtools
i                          Display process summary
ifmodeset                  Set the link operating mode for a network interface
ifmodeshow                 Display the link operating mode for a network
                           interface
interfaceshow              Display the FSPF (TM) interface information
interopmode                Displays/enables/disables Brocade switch
                           interoperability with switches from other
                           manufacturers
iodreset                   Turn off the in-order delivery (IOD) option
iodset                     Turn on the in-order delivery (IOD) option
iodshow                    Display the state of the in-order delivery option
ipaddrset                  Set ethernet and FC IP addresses
ipaddrshow                 Print ethernet and FC IP addresses
ipfilter                   Manage/display IP filters
iscsihelp                  Print iSCSI help info
islshow                    Display the current connections and status
killtelnet                 Terminate telnet/serial login sessions
                           interactively
licenseadd                 Adds license keys to switch
licensehelp                Print license help info
licenseidshow              Displays the system license ID
licenseport                Configure per-port POD license assignments
licenseremove              Removes a license key from this system
licenseshow                Displays current license keys
linkcost                   Set or print the FSPF cost of a link
login                      Login as a new user
logout                     Logout from remote session
loopporttest               Functional test of L-port M->M path on a loop.
lsdbshow                   Displays the FSPF link state database
memshow                    Display memory usage in the system.
minicycle                  Functional test of internal and external transmit
                           and receive paths at full speed.
minispropshow              Displays ASIC pair properties.
more                       Linux more command
mscapabilityshow           Display Management Server Capability.
msconfigure                Configure Management Server
msplatshow                 Display the Management Server Platform Database
msplatshowdbcb             Display the Management Server Database Control
                           Block
msplcleardb                Clear the Management Server Platform Database
                           fabric-wide
msplmgmtactivate           Activate the Management Server Platform Database
                           fabric-wide
msplmgmtdeactivate         Deactivate the Management Server Platform Database
                           fabric-wide
mstddisable                Disables the Management Server Topology Discovery
                           Management Service
mstdenable                 Enables the Management Server Topology Discovery
                           Management Service
mstdreadconfig             Display status of Management Server Topology
                           Discovery Service
myid                       Display the current login session details
nbrstateshow               Display FSPF (TM) neighbors' states
nbrstatsclear              Reset the FSPF (TM) interface counters
netstat                    Display network connections and statistics
nodefind                   Display all the devices' PID matching the given
                           world wide name
nsaliasshow                Display local Name Server information with Aliases
nsallshow                  Print global Name Server information
nscamshow                  Print local Name Server Cache information
nsshow                     Print local Name Server information information
nszonemember               Display the information of all the online devices
                           which are zoned with the given device.
opensource                 Display information on open source software
                           utilized in FabOS
passwd                     Set usernames and passwords
passwdcfg                  passwdcfg manages the password policies.
pathinfo                   Display routing information between two ports
pdshow                     Show information from Panic Dump file
perfaddeemonitor           Add end-to-end monitor
perfaddipmonitor           Add monitor for IP trafic frame count
perfaddreadmonitor         Add filter-based monitor - SCSI Read
perfaddrwmonitor           Add monitor - SCSI Read and Write
perfaddscsimonitor         Add monitor for SCSI frame count
perfaddusermonitor         Add filter-based monitor
perfaddwritemonitor        Add filter-based monitor - SCSI Write
perfcfgclear               Clear Performance settings from FLASH
perfcfgrestore             Restore Performance configuration from FLASH
perfcfgsave                Save Performance configuration to FLASH
perfclearalpacrc           Clears the CRC error count associated with a port
                           and Arbitrated Loop Physical Address (AL_PA).
perfcleareemonitor         Clears statistics counters of one or more
                           end-to-end performance monitors.
perfclearfiltermonitor     Clears counters of one or more filter-based
                           performance monitors.
perfdeleemonitor           Delete end-to-end monitor
perfdelfiltermonitor       Delete filter-based monitor
perfhelp                   Print Performance Monitoring help info
perfmonitorclear           Clear end-to-end/filter-based/ISL monitors
perfmonitorshow            Show end-to-end/filter-based/ISL monitors
perfsetporteemask          Set overall mask for end-to-end monitors
perfshowalpacrc            Get ALPA CRC count by port and ALPA
perfshoweemonitor          Show user-defined end-to-end monitors
perfshowfiltermonitor      Show filter-based monitors
perfshowporteemask         Show the current end-to-end mask
pkicreate                  Creates public key infrastructure (PKI) objects
pkiremove                  Removes existing public key infrastructure (PKI)
                           objects
pkishow                    Displays existing public key infrastructure (PKI)
                           objects
policy                     Configure IPSec encryption and authentication
                           algorithms
portalpashow               Show the ALPAs of a port
portbuffershow             Print the buffer allocations for the ports of a
                           quad
portcamshow                Display filter utilization
portcfg                    Create/Delete a new ip interface/route/arp entry on
                           the GigE port
portcfgdefault             Restore the port configuration to defaults
portcfgeport               Enable/Disable a port from becoming E_Port
portcfgexport              Sets a port to be an EX_Port and sets and displays
                           EX_Port configuration parameters.
portcfggport               Lock a port as a G_Port
portcfgislmode             Configure a port to be ISL R_RDY Mode
                           enabled/disabled
portcfglongdistance        Configure a Long Distance Port
portcfglport               Lock a port as a L_Port
portcfgnpivport            Enables and disables NPIV functionality on a port.
portcfgnport               Enable/disable N_Port capability for a port
portcfgpersistentdisable   Persistently disable a port
portcfgpersistentenable    Enable a persistently disabled port
portcfgshow                Displays port configuration settings.
portcfgspeed               Configure a port to a particular speed level
portcfgtrunkport           Configure a port for trunking
portcfgvexport             Sets a port to be an VEX_Port connected to FC-IP
                           and sets and displays VEX_Port configuration
                           parameters.
portcmd                    Execute commands (ping etc) on the GigE port
portdebug                  Set debug level and verbosity level of port modules
portdisable                Disable a specified port
portenable                 Enable a specified port
porterrshow                Print port error summary
portflagsshow              Display the port status bitmaps of all ports in a
                           switch
portledtest                Cycle user port LEDs.
portlogclear               Clear port activity log
portlogconfigshow          Display portlog configuration
portlogdisable             Disable portlog facility
portlogdump                Print port log (no page breaks)
portlogdumpport            Print port log (no page breaks)
portlogenable              Enables port log facility
portlogeventshow           Display information about port log events
portloginshow              Display port login information
portlogpdisc               Set or clear the debug_pdisc_flag
portlogreset               Enable portlog facility
portlogresize              Resize the port log
portlogshow                Print port activity log
portlogshowport            Print port activity log
portlogtypedisable         Disable port logging
portlogtypeenable          Enable port logging
portloopbacktest           Functional test of port N->N path.
portmirror                 Set a port's configuration to be disabled or
                           enabled
portname                   Assign or display the name associated with a port
portperfshow               Print port throughput numbers
portregtest                Write/read test of the ASIC SRAMs portregtest.
portrouteshow              Display various routing tables for a port
portshow                   Show configured ip interfaces/routes/arp entries on
                           the GigE Port
portstats64show            Display the 64-bit hardware statistics for a port
portstatsclear             Clear the status of a specified switch port
portstatsshow              Print hardware statistics
portswap                   Swaps area numbers
portswapdisable            Disable portswap feature
portswapenable             Enable portswap feature
portswapshow               Display port and area information
porttest                   Functional test on a live fabric. Starts porttest.
porttestshow               Retreive information from porttest.
portzoneshow               Displays the enforced zone type of the F/FL-ports
                           of a switch.
powerofflistset            sets slot power off list order
powerofflistshow           Displays slot power-off order.
psshow                     Print power supply status
quietmode                  Displays/enables/disables quietmode on telnet
                           session
reboot                     Reboot this processor
routehelp                  Print routing help info
saschiptest                Functional Test of Components in SAS Complex.
saspathtest                Data Path Test of the SAS complex.
secactivesize              Displays size of the active (security) database
secauthsecret              Creates/Manages DHCHAP secret key details
seccertutil                Creates/Manages/Displays third party PKI
                           certificates
secdefinesize              Displays size of the defined (security) database
secfabricshow              Displays security related fabric information
secfcsfailover             Forces primary role to this FCS switch
secglobalshow              Displays current internal security state
                           information
sechelp                    Displays information about security commands
secmodedisable             Disables secure mode
secmodeenable              Enables secure mode
secmodeshow                Displays whether secure mode is enabled or disabled
secnonfcspasswd            Sets the admin passwd for non-FCS switches
secpolicyabort             Aborts changes to defined policy
secpolicyactivate          Activates all policy sets
secpolicyadd               Adds members to an existing policy
secpolicycreate            Creates a new policy
secpolicydelete            Deletes an existing policy
secpolicydump              Displays all members of existing policies
secpolicyfcsmove           Moves a member in the FCS policy
secpolicyremove            Removes members from an existing policy
secpolicysave              Saves defined policy set and sends to all switches
secpolicyshow              Shows members of one or more policies
secstatsreset              Resets security statistics
secstatsshow               Displays security statistics
sectemppasswdreset         Resets temporary password
sectemppasswdset           Sets temporary password
sectransabort              Aborts current transaction
secversionreset            Resets version stamp
sensorshow                 Display sensor readings
setdbg                     Set debug level of the specified module
setesdmode                 Set or display ESD mode.
setmfgmode                 Set or display diagnostic MFG mode.
setmodem                   Enables or disables modem login to a control
                           processor (CP)
setsplbmode                Set or display SPLB mode.
setverbose                 Set verbosity level of the specified module
sfpshow                    Print Serial ID SFP information
shellflowcontroldisable    Disable xon-xoff flow control on console serial
                           port
shellflowcontrolenable     Enable xon-xoff flow control on console serial port
slotpoweroff               Removes power from a slot.
slotpoweron                Restores power to a slot.
slotshow                   Displays the status of all slots in the system.
sltest                     Serial link test of port N->N path.
snmpconfig                 Configure SNMP
snmpmibcapset              Set options for configuring SNMP Mib/Trap
                           Capability
snmpmibcapshow             Show SNMP Mib/Trap Configuration
spinfab                    Functional test of switch to switch ISL cabling and
                           trunk group operation.
spinjitter                 line-speed jitter measurement
spinsilk                   Functional test of internal and external transmit
                           and receive paths at full speed
sramretentiontest          Data retention test of the miscellaneous SRAMs in
                           ASIC.
statsclear                 Clear port and diagnostic statistics.
statstest                  Statistics counter test for the ASICs.
stopporttest               Terminate the running porttest.
supportffdc                Modifies or displays first-failure data capture
                           (FFDC) configuration.
supportftp                 set support Ftp parameters
supportsave                retrieve support data from switch to host
supportshow                Prints switch information for debugging purposes.
supportshowcfgdisable      Disables a group of commands under supportshow
                           command.
supportshowcfgenable       Enables a group of commands under supportshow
                           command.
supportshowcfgshow         Displays the groups of commands enabled for
                           display. by the supportshow command.
switchbeacon               Set switch beacon on or off
switchcfgpersistentdisable Persistently disable a switch
switchcfgpersistentenable  Enable a persistently disabled switch
switchcfgspeed             Configures all ports of the switch to a particular
                           speed level
switchcfgtrunk             Configure all ports on the switch for trunking
switchdisable              Disable this switch
switchenable               Enable this switch
switchname                 Print/set this switch's name
switchreboot               Halts and restarts the operational switch.
switchshow                 Print switch and port status
switchstatuspolicyset      Set policy parameters for overall switch status
switchstatuspolicyshow     Print policy parameters for overall switch status
switchstatusshow           Print overall switch status
switchuptime               Display the amount of time for which the switch is
                           up
syslogdfacility            Change the syslog facility
syslogdipadd               Add syslog daemon IP address
syslogdipremove            Remove syslog daemon IP address
syslogdipshow              Print the syslog daemon targets
sysshutdown                Provides a graceful shutdown to protect the switch
                           file systems.
systemverification         Run a suit of diagnostic tests on all switches in a
                           system.
tempshow                   Print temperature readings
timeout                    Set/show the IDLE timeout value for a login session
topologyshow               Display the unicast fabric topology
tracedump                  generate/remove trace dump or display trace dump
                           status
trackchangeshelp           Print Track Changes help info
trackchangesset            Configure alert for login/logout/config update
trackchangesshow           Displays status of track changes
trunkdebug                 Debug a trunk link failure
trunkshow                  Display trunking information
tsclockserver              Displays or sets the NTP server address
tstimezone                 Displays or sets the time zone
turboramtest               Turbo SRAM test for bloom ASICs.
txdpath                    Functional test of ASIC pair TXA TXD connections.
uptime                     Print how long switch has been up
urouteconfig               Configure a static route
urouteremove               Remove a static route
urouteshow                 Display unicast routing information
userconfig                 Display or configure user accounts
userrename                 Rename user login name
version                    Print firmware version
wwn                        Display or set the world wide name
zone                       Copies/Removes/Validates zone objects
zoneadd                    Add a member to a zone
zonecreate                 Create a zone
zonedelete                 Delete a zone
zonehelp                   Print zoning help info
zoneobjectcopy             Copies a zone object
zoneobjectexpunge          Expunges a zone object
zoneobjectrename           Rename a zoning Object
zoneremove                 Remove a member from a zone
zoneshow                   Print zone information
goals:admin> wwn
10:00:00:05:1e:35:7f:aa

goals:admin>

Comments

Popular posts from this blog

esxi-host-shows-disconnected-vmware

ESXi : Lost uplink redundancy on virtual switch "vSwitch0". Physical NIC vmnic0 is down

Virtual machines appear as invalid or orphaned in vCenter Server